T/CEC 143-2017 超高性能混凝土电杆

T/CEC 143-2017 Super High Performance Concrete Poles

团体标准 中文(简体) 现行 页数:36页 | 格式:PDF

基本信息

标准号
T/CEC 143-2017
标准类型
团体标准
标准状态
现行
中国标准分类号(CCS)
国际标准分类号(ICS)
发布日期
2017-05-15
实施日期
2017-08-01
发布单位/组织
-
归口单位
中国电力企业联合会
适用范围
本标准规定了超高性能混凝土电杆的产品分类、原材料、混凝土配制及构造、技术要求、试验方法、检验规则、标志与产品合格证、贮存与运输等。 本标准适用于电力、通讯及接触网架空线路的电杆、照明支柱和信号机柱等

发布历史

研制信息

起草单位:
中国电力科学研究院、鞍山铁塔开发研制中心、鞍山远达电网工程有限公司、国网河北省电力公司、河北省电力勘测设计研究院、北京交通大学、国网浙江省电力公司丽水供电公司、重庆宏达水泥制品有限公司
起草人:
邢海军、祁锦明、李正、程永锋、安明喆、李占岭、刘光旺、马建春、李振福、张子富、吴华明、韩军科、吴春生、耿景都、王灿灿、李清华、武坤、朱彬荣、初金良、王旭明
出版信息:
页数:36页 | 字数:- | 开本: -

内容描述

ICS

29.240.20

K47备案号:

53939-2016

中国电力企业联合会标准

T/CEC143—2017

超高性能混凝土电杆

Ultra-Highperformanceconcretepole

2017-05-15发布2017-08-01实施

中国电力企业联合会发布

T/CEC143—2017

目次

前

言················································································································································

··················Ⅱ

1范

围··············································································································································

················1

2规范性引用文

件··········································································································································1

3术语和定

义··············································································································································

····2

4产品分

类··············································································································································

········2

5原材料、混凝土配制及构

造·····················································································································12

5.1原材

料··············································································································································

······12

5.2混凝土配

制··············································································································································

13

5.3构

造·············································································································································

···········14

6技术要

求················································································································································

····15

6.1混凝土抗压强

度·······································································································································15

6.2耐久性

能··············································································································································

···15

6.3外观质

量··············································································································································

···15

6.4尺寸允许偏

差··········································································································································16

6.5保护层厚

度··············································································································································

17

6.6力学性

能··············································································································································

···17

6.7抗撞击性

能··············································································································································

17

7试验方

法················································································································································

····18

7.1混凝土抗压强

度·······································································································································18

7.2混凝土耐久性

能·······································································································································18

7.3外观质量、尺

寸·······································································································································18

7.4保护层厚

度··············································································································································

19

7.5力学性

能··············································································································································

···19

7.6抗撞击性

能··············································································································································

19

8检验规

则················································································································································

····19

8.1检验分

类··············································································································································

···19

8.2出厂检

验··············································································································································

···19

8.3型式检

验··············································································································································

···20

9标志与产品合格

证····································································································································21

9.1标

志·············································································································································

···········21

9.2产品合格

证··············································································································································

22

10贮存与运

输··············································································································································2

2

10.1贮

存··············································································································································

········22

10.2运

输··············································································································································

········23

附录A(规范性附录)电杆力学性能试验方

法························································································24

附录B(规范性附录)电杆抗撞击性能试验方

法····················································································29

I

T/CEC143—2017

前言

本标准依据GB/T1.1—2009《标准化工作导则第1部分:标准的结构和编写》给出的规则

起草。

本标准由中国电力企业联合会提出。

本标准由全国架空线路标准化技术委员会(SAC/TC202)归口。

本标准起草单位:中国电力科学研究院、鞍山铁塔开发研制中心、鞍山远达电网工程有限公司、

国网河北省电力公司、河北省电力勘测设计研究院、北京交通大学、国网浙江省电力公司丽水供电公

司、重庆宏达水泥制品有限公司。

本标准起草人:邢海军、祁锦明、李正、程永锋、安明喆、李占岭、刘光旺、马建春、李振福、

张子富、吴华明、韩军科、吴春生、耿景都、王灿灿、李清华、武坤、朱彬荣、初金良、王旭明。

本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二

条一号,100761)。

II

T/CEC143—2017

超高性能混凝土电杆

1范围

本标准规定了超高性能混凝土电杆的产品分类,原材料、混凝土配制及构造,技术要求,试验方

法,检验规则,标志与产品合格证,贮存与运输等。

本标准适用于电力、通信及接触网架空线路的电杆、照明支柱和信号机柱等。

2规范性引用文件

下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本

文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB175通用硅酸盐水泥

GB/T700碳素结构钢

GB1499.1钢筋混凝土用钢第1部分:热轧光圆钢筋

GB1499.2钢筋混凝土用钢第2部分:热轧带肋钢筋

GB/T1591低合金高强度结构钢

GB/T1596用于水泥和混凝土中的粉煤灰

GB2694输电线路铁塔制造技术条件

GB/T5223预应力混凝土用钢丝

GB/T5223.3预应力混凝土用钢棒

GB/T5224预应力混凝土用钢绞线

GB8076混凝土外加剂

GB13788冷轧带肋钢筋

GB/T18046水泥和混凝土中的粒化高炉矿渣粉

GB/T27690砂浆和混凝土用硅灰

GB31387活性粉末混凝土

GB50010混凝土结构设计规范

GB/T50081普通混凝土力学性能试验方法标准

GB/T50082普通混凝土长期性能和耐久性能试验方法标准

GB/T50107混凝土强度检验评定标准

GB50119混凝土外加剂应用技术规范

GB50204混凝土结构工程施工质量验收规范

GB50205钢结构工程施工质量验收规范

JC/T540混凝土制品用冷拔低碳钢丝

JC/T874水泥用硅质原料化学分析方法

JGJ18钢筋焊接及验收规程

JGJ52普通混凝土用砂、石质量及检验方法标准

JGJ63混凝土用水标准

JGJ107钢筋机械连接技术规程

TB/T2922.1铁路混凝土用骨料碱活性试验方法岩相法

1

T/CEC143—2017

TB/T2922.5铁路混凝土用骨料碱活性试验方法快速砂浆棒法

3术语和定义

下列术语和定义适用于本文件。

3.1

超高性能混凝土ultra-highperformanceconcrete;UHPC

以水泥、矿物掺合料、细骨料、添加剂等原料生产的具有超高强度和耐久性能的细骨料混凝土。

3.2

钢筋超高性能混凝土电杆reinforcedultra-highperformanceconcretepole

纵向受力钢筋为普通钢筋的超高性能混凝土电杆。

3.3

预应力超高性能混凝土电杆prestressedultra-highperformanceconcretepole

纵向受力钢筋全部为预应力钢筋,且正常使用状态下截面上混凝土不出现裂缝的超高性能混凝土

电杆。

3.4

部分预应力超高性能混凝土电杆partiallyprestressedultra-highperformanceconcretepole

纵向受力钢筋由预应力钢筋与普通钢筋组合或全部为预应力钢筋,且正常使用状态下截面上混凝

土允许出现裂缝但最大裂缝宽度不超过允许值的超高性能混凝土电杆。

3.5

薄壁超高性能混凝土电杆ultra-highperformanceconcretethin-wallpole

壁厚在30mm及以下的超高性能混凝土电杆。

3.6

胶凝材料binderorcementitiousmaterials

用于配制混凝土的水泥和矿物掺合料的总称。

3.7

标准检验弯矩standardtestbendingmoment

正常使用状态下电杆检验位置处的检验弯矩值。

3.8

承载力检验弯矩testbendingmomentofbearingcapacity

承载能力极限状态下电杆检验位置处的检验弯矩值。

3.9

抗撞击性能impactresistance

电杆抵抗在运输、装卸、安装及使用过程中发生的跌落、撞击及刮碰等荷载作用的能力。

3.10

气孔stomata

浇筑过程中混凝土混入气泡而导致产品出现的微小孔。

4产品分类

4.1产品按外形分为锥形杆(代号为Z)和等径杆(代号为D),截面宜为环形,也可采用方形或多边

形。产品按不同配筋方式分为钢筋超高性能混凝土电杆(代号为G)、预应力超高性能混凝土电杆(代

号为Y)和部分预应力超高性能混凝土电杆(代号为BY)三种。超高性能混凝土电杆锥形杆和等径杆

均有整根杆和组装杆,组装杆杆段连接方式可分为法兰连接、焊接和插接。

4.2产品按锥度分为1/75锥度(代号为A)、1/50锥度(代号为B)和1/37.5锥度(代号为C),也可

2

T/CEC143—2017

采用其他锥度。

4.3电杆梢径(或直径)、长度、标准检验荷载、标准检验弯矩、承载力检验弯矩(承载力检验弯

矩为标准检验弯矩的2倍),如表1~表4所示,也可生产其他标准检验弯矩的电杆。

4.4电杆与基础连接方式可分为直埋式和根部法兰式,如图1所示。

说明:

——杆长;

L1——荷载点高度;

L2——支持点高度;

L3——梢端至荷载点距离;

L——根径;

D——梢径;

d——壁厚。

δ

图1电杆与基础连接方式

4.5产品按外形代号、锥度(或锥度代号)、电杆梢径(或直径)、杆长、标准检验弯矩(或标准检验

荷载代号)、品种代号和混凝土类型顺序进行标记。

注1:梢径(或直径)单位为mm;杆长单位为m;标准检验荷载单位为kN;标准检验弯矩单位为kN·m。

注2:锥形杆标准检验弯矩指支持点断面处的标准检验弯矩。

示例1:

锥度为1/75,梢径为190mm、杆长为12m、标准检验弯矩为39kN·m的部分预应力超高性能混凝土锥形杆,其标

记为ZAφ190×12×39×BY(UHPC)。

示例2:

锥度为1/60,梢径为230mm、杆长为15m、标准检验荷载为K级的钢筋超高性能混凝土锥形杆,其标记为Z60

φ230×15×K×G(UHPC)。

示例3:

直径为300mm的等径杆、杆长为9m、标准检验弯矩为50kN•m的钢筋超高性能混凝土锥形杆,其标记为Dφ300

×9×50×G(UHPC)。

3

T/CEC143—2017

4

T/CEC143—2017

5

T/CEC143—2017

6

T/CEC143—2017

7

T/CEC143—2017

8

T/CEC143—2017

9

T/CEC143—2017

10

T/CEC143—2017

11

T/CEC143—2017

5原材料、混凝土配制及构造

5.1原材料

5.1.1胶凝材料

5.1.1.1水泥宜采用强度等级不低于42.5级的非早强型硅酸盐水泥或普通硅酸盐水泥,其性能应符合

GB175的规定。

5.1.1.2粉煤灰应采用Ⅰ级粉煤灰,其性能应符合GB/T1596的规定;硅灰应符合GB/T27690的规

定;粒化高炉矿渣粉应采用S95以上的矿渣粉,其性能应符合GB/T18046的规定。当采用其他矿物掺

合料时,应通过试验进行验证,确定混凝土性能满足工程应用要求后方可使用。

5.1.2集料

5.1.2.1集料宜采用粒径0.16mm~1.25mm的石英砂,粒级按粗粒径砂(1.25mm~0.63mm)、中粒径

砂(0.63mm~0.315mm)和细粒径砂(0.315mm~0.16mm)三个粒级,同一粒级中超过粒径范围的颗

粒含量不得大于同一粒级石英砂总量的5%,且不得含有泥块。其技术指标应符合表5的要求。

表5石英砂的技术指标%

项目技术指标

SiO2含量≥97

氯离子含量≤0.02

硫化物及硫酸盐含量≤0.50

云母含量≤0.50

含泥量≤0.50

5.1.2.2石英砂的筛分应按照JGJ52的规定进行检验;石英砂的SiO2含量应按JC/T874的规定进

行检验;石英砂的氯离子含量、硫化物及硫酸盐含量、云母含量及泥含量应按JGJ52的规定进行

检验。

5.1.2.3集料可选用级配Ⅱ区的中砂,粒径大于3mm的颗粒含量宜小于5%。天然砂的含泥量和泥块

含量应符合表6的要求;人工砂的石粉含量应符合表7的要求。集料碱活性按TB/T2922.1的规定检验

矿物组成和碱活性类型,不应使用碳酸盐类碱活性矿物。硅质骨料按照TB/T2922.5的规定进行碱活性

评定,当14d砂浆棒长度膨胀率小于等于0.10%时,将骨料评定为非碱-硅酸反应活性骨料,可正常

使用;当长度膨胀率大于0.10%且小于等于0.20%时,应采用有效抑制措施,并证明有效方可使用;当

长度膨胀率大于0.20%时,严禁使用。砂的其他性能应符合JGJ52的规定。

表6天然砂的含泥量和泥块含量%

项目含泥量泥块含量

指标≤1.0≤0.5

表7人工砂的石粉含量%

项目指标

<1.4≤5.0

石粉含量

MB

≥1.4≤3.0

MB

12

T/CEC143—2017

5.1.3水

混凝土拌和用水应符合JGJ63的规定。

5.1.4外加剂

外加剂应符合GB8076和GB50119的规定。减水剂宜选用高性能减水剂,减水率宜大于

30%。严禁使用氯盐类外加剂或其他对钢筋有腐蚀作用及影响混凝土蒸养性能的外加剂。

5.1.5钢纤维

钢纤维宜采用高强度圆截面直纤维,其性能指标应符合表8的规定,其性能检验应按GB31387进行。

表8钢纤维的性能指标

项目性能指标

抗拉强度(MPa)