DB22/T 5138-2023 建筑机电管线工程抗震支吊架技术标准

DB22/T 5138-2023 Building mechanical and electrical pipeline earthquake resistant support system technical standards

吉林省地方标准 简体中文 现行 页数:39页 | 格式:PDF

基本信息

标准号
DB22/T 5138-2023
标准类型
吉林省地方标准
标准状态
现行
中国标准分类号(CCS)
国际标准分类号(ICS)
发布日期
2023-04-04
实施日期
2023-04-04
发布单位/组织
吉林省市场监督管理厅
归口单位
-
适用范围
-

发布历史

研制信息

起草单位:
起草人:
出版信息:
页数:39页 | 字数:- | 开本: -

内容描述

吉林省工程建设地方标准

建筑机电管线工程抗震支吊架技术标准

Technicalstandardforseismicbracingofbuilding

electromechanicalpipelineengineering

DB22/T5138-2023

主编部门:吉林省建设标准化管理办公室

批准部门:吉林省住房和城乡建设厅

吉林省市场监督管理厅

施行日期:2023年4月4日

2023·长春

吉林省住房和城乡建设厅

吉林省市场监督管理厅

通告

第620号

吉林省住房和城乡建设厅吉林省市场监督管理厅

关于发布《纤维增强聚乙烯给水排水管道工程技术

标准》等5项吉林省工程建设地方标准的通告

现批准《纤维增强聚乙烯给水排水管道工程技术标准》《城市

轨道交通岩土工程勘察标准》《既有建筑幕墙可靠性鉴定标准》《海

绵城市建设工程检测技术标准》《建筑机电管线工程抗震支吊架技术

标准》为吉林省工程建设地方标准,编号依次为:DB22/T5007-2023、

DB22/T5135-2023、DB22/T5136-2023、DB22/T5137-2023、DB22/T

5138-2023,自发布之日起实施。原《纤维增强给水管道工程技术标准》

DB22/T5007-2018同时废止。

吉林省住房和城乡建设厅

吉林省市场监督管理厅

2023年4月4日

前言

根据吉林省住房和城乡建设厅关于下达《2021年全省工程建

设地方标准制定(修订)计划(二)》的函(吉建函〔2021〕694

号)要求,标准编制组进行广泛的调查研究,认真总结实践经验,

参考有关国内外先进标准,并在广泛征求意见的基础上,制定本标

准。

本标准的主要内容:1总则;2术语;3基本规定;4材料;

5设计;6施工;7验收。

本标准由吉林省建设标准化管理办公室负责管理,由吉林省建

筑科学研究设计院负责具体技术内容的解释。

本标准在执行过程中如发现需要修改和补充之处,请将意见和

有关资料反馈至吉林省建设标准化管理办公室(长春市民康路519

号,邮编130041,电子邮箱:jljsbz@126.com),以供今后修订时

参考。

本标准主编单位:吉林省建筑科学研究设计院

深圳市固耐达科技有限公司

本标准参编单位:吉林省建苑设计集团有限公司

机械工业第九设计研究院有限公司

本标准主要起草人员:石永桂孙鹏褚毅王红伟

吕曾王健鹏孙秀刚张雪楠

刘晓王飞解放冯海华

王毅李柠周林李志国

赵阳王岚兰郭小强赵岩

刘硕张军闯李想崔永生

马根华卢强王云松张哲

唐明刘洪洋李佳琳赵冰冶

张龙龙刘晨苏德东万志钢

逯宏源李一田朱云潞周登科

李肖松

本标准主要审查人员:周毅陶乐然周庆杰宗有志

马青龙李永红杨晓雨

目次

1总则··························································································1

2术语··························································································2

3基本规定····················································································3

4材料··························································································4

5设计··························································································0

5.1一般规定·············································································0

5.2给排水抗震支吊架······························································1

5.3采暖、通风、空调及防排烟抗震支吊架···························1

5.4电气抗震支吊架··································································1

5.5燃气抗震支吊架··································································2

5.6抗震支吊架计算··································································2

5.7抗震支吊架布置··································································4

6施工··························································································7

6.1一般规定·············································································7

6.2施工准备·············································································7

6.3施工要点·············································································8

7验收·························································································10

7.1一般规定············································································10

7.2主控项目············································································11

7.3一般项目············································································12

本标准用词说明·············································································13

引用标准名录·················································································14

附:条文说明·················································································16

1总则

1.0.1为规范建筑机电管线工程抗震支吊架设计、施工及验收,确

保工程质量,制定本标准。

1.0.2本标准适用于建筑抗震设防烈度为6度~8度地区的新建、

改建和扩建的建筑机电管线工程抗震支吊架设计、施工及验收。

1.0.3建筑机电管线工程抗震支吊架的设计、施工及验收,除应符

合本标准外,尚应符合国家现行有关标准的规定。

1

2术语

2.0.1抗震支吊架seismicbracing

与建筑结构体可靠连接,并能承担地震作用的支吊架。

2.0.2侧向抗震支吊架lateralseismicbracing

斜撑与管线横截面平行的抗震支吊架。

2.0.3纵向抗震支吊架longitudinalseismicbracing

斜撑与管线横截面垂直的抗震支吊架。

2.0.4单管(杆)抗震支吊架singletubeseismicbracing

由一根承重吊杆和抗震斜撑组成的抗震支吊架。

2.0.5门型抗震支吊架door-shapedseismicbracing

由两根及以上承重吊杆和横梁、抗震斜撑组成的抗震支吊架。

2.0.6抗震支撑seismicbracing

通过支撑将地震水平作用力传递给建筑结构的构件

2.0.7抗震斜撑seismicdiagonalbracing

通过斜撑,将地震水平作用力传递给建筑结构的构件。

2.0.8抗震连接构件structureconnectingcomponent

用于连接抗震斜撑的单独或组合的构件。

2

3基本规定

3.0.1抗震支吊架应符合现行国家标准《建筑抗震支吊架通用技术

条件》GB/T37267的有关规定。

3.0.2抗震支吊架的所有构件除C型槽钢、吊杆可进行现场切割

外,其他产品不得进行现场加工。

3.0.3组成抗震支吊架的所有构件应采用装配式成品构件,连接紧

固件的构造应便于安装。

3

4材料

4.0.1抗震支吊架主体应采用Q235B级及以上碳钢或者不锈钢等

材料,碳钢材料化学成分应符合现行国家标准《碳素结构钢》GB/T

700的规定,不锈钢材料化学成分应符合现行国家标准《不锈钢和

耐热钢牌号及化学成分》GB/T20878的规定。

4.0.2管道连接构件衬垫材料应采用氯化丁基橡胶或三元乙丙橡

胶。其质量要求应符合现行国家标准《不饱和橡胶中饱和橡胶的鉴

定》GB/T16583的规定。

4.0.3紧固件的质量应符合现行国家标准《紧固件机械性能螺栓、

螺钉和螺柱》GB/T3098.1、《紧固件机械性能螺母》GB/T3098.2、

《紧固件机械性能不锈钢螺栓、螺钉和螺柱》GB/T3098.6和《紧

固件机械性能不锈钢螺母》GB/T3098.15的规定。

4.0.4垫圈的质量应符合现行国家标准《标准型弹簧垫圈》GB/T

93、《平垫圈C级》GB/T95的规定。

4.0.5锚栓的质量应符合现行行业标准《混凝土用机械锚栓》JG/T

160的规定。

4.0.6抗震斜撑的质量应符合现行国家标准《通用冷弯开口型钢》

GB/T6723的规定。

4.0.7柔性斜拉钢索的性能应符合符合现行国家标准《不锈钢丝绳》

GB/T9944的规定。

4.0.8锚栓性能应符合现行行业标准《混凝土用机械锚栓》JG/T

160的有关规定,所使用的机械锚栓需通过S类1级的技术要求,

锚栓的选用应符合现行行业标准《混凝土结构后锚固技术规程》JGJ

145的有关规定。

4.0.9抗震连接构件与混凝土结构连接的锚栓,应采用具有机械

锁键效应的扩底锚栓,不得使用膨胀锚栓。抗震连接构件与钢结

4

构连接,应采用专用夹具进行连接。所有螺栓的性能不得低于8.8

级。

4.0.10材料、防腐、耐火极限应符合下列规定:

1C型槽钢应符合现行国家标准《碳素结构钢》GB/T700的

规定;

2构件应进行防腐处理,根据使用环境类别确定防腐等级,

并应符合现行国家标准《人造气氛腐蚀试验盐雾试验》GB/T10125

的规定,C