DB11/T 1008-2024 建筑光伏系统安装及验收规程

DB11/T 1008-2024 Installation and acceptance procedures for building photovoltaic systems

北京市地方标准 简体中文 现行 页数:54页 | 格式:PDF

基本信息

标准号
DB11/T 1008-2024
标准类型
北京市地方标准
标准状态
现行
中国标准分类号(CCS)
国际标准分类号(ICS)
发布日期
2024-03-29
实施日期
2024-07-01
发布单位/组织
北京市市场监督管理局
归口单位
北京市住房和城乡建设委员会
适用范围
-

发布历史

研制信息

起草单位:
起草人:
出版信息:
页数:54页 | 字数:- | 开本: -

内容描述

北京市地方标准DB

编号:DB11/T1008-2024

建筑光伏系统安装及验收规程

Installationandacceptancespecification

forsolarPVsystemoncivilbuildings

2024-03-29发布2024-07-01实施

联合发布

北京市地方标准

建筑光伏系统安装及验收规程

Installationandacceptancespecification

forsolarphotovoltaicsystemoncivilbuildings

编号:DB11/T1008-2024

主编部门:北京城建科技促进会

中建一局集团第五建筑有限公司

中铁二十二局集团电气化工程有限公司

批准部门:北京市市场监督管理局

施行日期:2024年07月01日

2024年北京

DB11/T1008-2024

前言

根据北京市市场监督管理局《2021年北京市地方标准制修订项目计划》

(京市监发〔2021〕19号)的要求,规程编制组经广泛调查研究,认真总结

实践经验,参考国内相关标准,并在广泛征求意见的基础上,修订本规程。

本规程的主要技术内容是:1总则;2术语;3基本规定;4光伏组件与

构件安装;5电气设备安装;6防雷接地系统安装;7施工安全;8检查调试;

9质量验收;10运行维护。

本规程修订的主要技术内容是:

1.细化了基本要求,增加了光伏系统设计要求施工要求等内容;

2.光伏方阵安装与构件安装合并为一章,并进行细化;

3.调整、细化了电气设备安装内容,细化完善了防雷接地要求;

4.增加了施工安全要求;

5.调整了检查与调试内容;

6.增加了系统验收的分项划分、检验批划分和具体的验收项目,验收项

目按构造与连接、组件与构件、电气系统、防雷接地、系统功能等分项工程

确定了主控项目和一般项目内容。

本规程由北京市住房和城乡建设委员会和北京市市场监督管理局共同

负责管理,由北京市住房和城乡建设委员会归口并负责组织实施,北京城建

科技促进会负责具体技术内容的解释。执行过程中如有意见或建议,请寄送

北京城建科技促进会(北京市西城区广莲路1号,北京建工大厦A座906

室;邮编:100055;电话:010-63965212;电子邮箱:143c@),以

供今后修订时参考。

本规程主编单位:北京城建科技促进会

中建一局集团第五建筑有限公司

中铁二十二局集团电气化工程有限公司

本规程参编单位:北京市建筑节能与建筑材料管理事务中心

航天规划设计集团有限公司

北京城建亚泰建设集团有限公司

DB11/T1008-2024

北京城建七建设工程有限公司

北京京能建设集团有限公司

浙江金贝能源科技有限公司

上海宝冶集团有限公司

北京建工新型建材有限责任公司

住房和城乡建设部科技与产业化发展中心

北京东方雨虹防水技术股份有限公司

宝都国际新材料有限公司

天普新能源科技有限公司

中国建筑第二工程局有限公司

中建中环新能源有限公司

华为数字能源技术有限公司

本规程主要起草人员:王建明刘嘉茵徐广衍牛寅平张梅向振宇

吴胜通夏寅飞杜苍松魏巍于成龙邵珺

胡纯星戴磊王珊珊赫然许宁陈慧娜

朱运超李仁星周一萌吕燕柏潘宏宇石立国

焦道伟宋晓鑫李明辉徐增辉陈志中谢艳峰

张永超苏小东陈峰张程浩裴海清侯隆澍

赵加亮高峰王冬雁杨朝刘东超李响

胡京波江海新尹宝泉

本规程主要审查人员:鞠晓磊周卫新李栋李军张昕宇叶健

乔泊徐征

DB11/T1008-2024

目次

1总则......................................................................................................................................1

2术语......................................................................................................................................2

3基本规定......................................................................................................................................3

4光伏组件与构件安装...................................................................................................................5

4.1一般规定...............................................................................................................................5

4.2光伏组件安装.......................................................................................................................5

4.3光伏构件安装.......................................................................................................................6

5电气设备安装..............................................................................................................................8

5.1一般规定...............................................................................................................................8

5.2汇流箱...................................................................................................................................8

5.3逆变器...................................................................................................................................9

5.4交直流配电柜.....................................................................................................................10

5.5线缆敷设与连接.................................................................................................................11

5.6蓄电池组及充放电控制器..................................................................................................13

6防雷接地系统安装....................................................................................................................15

7施工安全....................................................................................................................................17

8检查调试....................................................................................................................................18

8.1安全性检查.........................................................................................................................18

8.2光伏方阵检查.....................................................................................................................18

8.3电气设备检查.....................................................................................................................19

8.4系统性能调试.....................................................................................................................20

9质量验收....................................................................................................................................23

9.1一般规定.............................................................................................................................23

9.2构造连接与支撑.................................................................................................................24

9.3组件.....................................................................................................................................26

9.4电气系统.............................................................................................................................27

9.5防雷接地.............................................................................................................................29

9.6系统功能.............................................................................................................................30

10运行维护..................................................................................................................................32

10.1一般规定...........................................................................................................................32

10.2日常维护管理...................................................................................................................32

10.3定期检查...........................................................................................................................33

附录A光伏系统施工质量验收表格...........................................................................................34

本规程用词说明............................................................................................................................36

引用标准名录................................................................................................................................37

附:条文说明................................................................................................................................38

DB11/T1008-2024

Contents

1Generalprovinces..........................................................................................................................1

2Terms..............................................................................................................................................2

3Basicrequirements.........................................................................................................................3

4InstallationofPVmodulesandPVcomponents............................................................................5

4.1Generalrequirements···················································································5

4.2PVmodules·······························································································5

4.3PVcomponents··························································································6

5Installationofelectricsystem........................................................................................................8

5.1Generalrequirements···················································································8

5.2Combinerbox····························································································8

5.3Connectedinverter······················································································9

5.4AC/DCpowerdistributionbox·······································································10

5.5Layandlinkofwirecable·············································································11

5.6Galvanicbatteryandcharge/dischargecontroller··················································13

6Installationoflightning-protectionsystem..................................................................................15

7Constructionsafety......................................................................................................................17

8Checkandadjust..........................................................................................................................18

8.1Safetycheck·····························································································18

8.2CheckandadjustofPVarray·········································································18

8.3Electriccheck···························································································19

8.4Adjustofsystemfunction·············································································20

9Qualityacceptance.......................................................................................................................23

9.1Generalrequirements··················································································23

9.2Structureconnectingandsupport····································································24

9.3PVmodulesandcomponents·········································································26

9.4Electricsystem··························································································27

9.5Lightning-protection···················································································29

9.6Systemfunction·························································································30

10Operationmaintenance..............................................................................................................32

10.1Generalrequirements·················································································32

10.2Routineinspection····················································································32

10.3Periodicinspection····················································································33

AppendixAAcceptancetablesofPVsystemengineering.............................................................34

Explanationwordinginthisstandard..............................................................................................36

Listofquotedstandards..................................................................................................................37

Addition:Explanationofprovisions...............................................................................................38

DB11/T1008-2024

1总则

1.0.1为加强太阳能光伏发电系统在建筑中的推广应用,促进光伏系统与建筑的

结合,规范光伏系统的安装、验收与运行维护,制定本规程。

1.0.2本规程适用于北京市行政区域内新建、改建和扩建建筑的光伏系统安装、

验收与运行维护。

1.0.3建筑光伏系统的安装、验收与运行维护,除应符合本规程的规定外,尚应

符合国家和北京市现行有关标准的规定。

1

DB11/T1008-2024

2术语

2.0.1建筑光伏发电系统buildingmountedsolarphotovoltaicsystem

安装在建筑上的利用太阳电池的光伏效应将太阳辐射能直接转换成电能的

发电系统。本规程中简称光伏系统。

2.0.2光伏组件photovoltaicmodule(PVmodule)

具有封装及内部联结的、能单独提供直流电流输出的最小不可分割的太阳

电池组合装置。

2.0.3光伏构件photovoltaicmodulecomponents

工厂模块化预制的具备建筑构件功能的光伏组件。

2.0.4光伏幕墙photovoltaiccurtainwall

含有光伏构件的幕墙。

2.0.5光伏方阵PVarray

由若干个光伏组件在机械和电气上按一定方式组装在一起,并且有固定的

支撑结构而构成的直流发电单元。

2.0.6光伏方阵方位角azimuthangleofPVarray

光伏方阵向阳面的法线在水平面上的投影与正南方向的夹角(向东偏设定

为负角度,向西偏设定为正角度),本规程中简称方阵方位角。

2.0.7光伏方阵倾角tiltangleofPVarray

光伏组件所在平面与水平面的夹角,本规程中简称方阵倾角。

2.0.8汇流箱combinerbox(combiningmanifolds)

在光伏发电系统中将若干个光伏组件串并联汇流后接入的装置。

2.0.9并网光伏系统grid-connectedPVsystem

与公共电网连接的光伏系统。

2.0.10并网接口utilityinterface

光伏系统与公共电网配电系统之间相互连接的公共连结点。

2.0.11并网逆变器grid-connectedinverter

将来自光伏方阵或光伏组件的直流电变换为符合电网要求的交流电馈入电

网并同时具有各种保护功能的设备。

2

DB11/T1008-2024

3基本规定

3.0.1建筑光伏系统应符合国家现行标准《建筑节能与可再生能源利用通用规范》

GB55015、《建筑光伏系统应用技术标准》GB/T51368、《建筑新能源应用设计规

范》DB11/T1774的规定。

3.0.2接入公用电网的光伏系统应符合现行国家标准《光伏系统并网技术要求》

GB/T19939的规定。

3.0.3光伏构件在建筑群体中的安装位置应合理,光伏构件周围的环境设施与绿

化种植不应对光伏构件的采光形成遮挡。

3.0.4材料和构配件进场后应进行质量检查和抽样复验。

3.0.5光伏系统应不影响建筑消防设施的安全运行。

3.0.6光伏系统各组成部分在建筑中的安装位置应合理布置,并应满足其所在部

位的建筑防水、排水和系统的检修、更新与维护的要求。

3.0.7光伏构件直接构成建筑围护结构时应与建筑周围环境相协调,应满足所在

部位的结构安全和建筑围护功能的要求,并且不应对建筑形体完整构成破坏。

3.0.8带储能装置的小型光伏系统的蓄电池、并网逆变器、计量仪表、监控器等

设备应安装在维护、观察、记录方便的位置。

3.0.9并网光伏系统与公共电网之间应设隔离装置。光伏系统在并网处应设置并

网专用低压开关箱或开关柜,并设置专用标识和“警告”、“双电源”提示性文字

和符号。

3.0.10光伏系统的安装应符合设计要求,并应按设计要求单独编制施工方案和采

取相应安全措施。

3.0.11光伏系统安装前应具备以下条件:

1设计文件齐备;

2并网接入手续齐全;

3施工组织设计或施工方案已通过批准;

4建筑、场地、电源和道路等条件能满足正常施工需要;

5预留基座、孔洞、预埋件、预埋管和相关设施符合设计图纸的要求,并已

验收合格。

3.0.12光伏系统的施工不应破坏建筑物的结构和建筑物的附属设施,不应影响建

3

DB11/T1008-2024

筑物在设计使用年限内承受各种荷载的能力。

3.0.13光伏系统的零部件及配套设备应符合现行国家标准《建筑设计防火规范》

GB50016中建筑构件和附着物防火等级的规定。

3.0.14完成方阵支架施工并安装完光伏组件后应先对已完成项目设施和设备采

取保护措施,再进入电气施工。

3.0.15光伏系统施工应做好施工记录。光伏系统工程质量验收应按本规程附录A

的规定进行质量验收记录,并填写系统验收报告。

3.0.16光伏构件上应标有带电警告标识。安装于可上人屋面的光伏系统的场所应

具有人员出入管理制度,并加围栏。

4

DB11/T1008-2024

4光伏组件与构件安装

4.1一般规定

4.1.1光伏组件、配件、材料的数量、性能、色彩等应符合设计文件要求,并具

有产品合格证明文件。

4.1.2光伏组件和构件进场后应对其品种、规格、性能进行检查和验收,质量应

符合国家现行产品标准和设计文件的规定,并应对发电功率、转换效率进行复验。

4.1.3光伏方阵处应设警告标识,并应按设计要求可靠地固定在支架或连接件上。

4.1.4方阵应排列整齐,光伏组件之间的连接件应便于拆卸和更换。

4.2光伏组件安装

4.2.1光伏组件基础应符合下列规定:

1光伏组件支架基座应按设计要求的位置、数量设置,基座应牢固、整齐;

2基座与建筑主体结构应连接牢固,钢筋混凝土基座的主筋应锚固在主体结

构内;

3预埋件与基座之间的空隙,应采用细石混凝土填捣密实;

4屋面基座施工完工后应做防水处理,并应符合现行国家标准《屋面工程质

量验收规范》GB50207和北京市地方标准《屋面防水技术标准》DB11/T1945的

规定;

5钢基座及混凝土基座顶面的预埋件,应按设计要求的防腐级别涂上防腐涂

料,并妥善保护。

4.2.2光伏组件安装应符合下列规定:

1光伏组件的拆箱和搬运应按照产品的相关操作说明进行;

2安装前应对各光伏组件进行检查,测量每个组件的开路电压、短路电流等

技术参数;

3对组件按照其技术参数进行分类,使最佳工作电流相近的串联在一起,最

佳工作电压相近的并联在一起;

4用钢螺栓或专用卡件将所有的组件固定在安装支架上;

5按照组件串并联的设计要求,用导线将组件的正、负极进行连接,导线电

缆之间的连接必须可靠。宜用带保护皮的不锈钢夹、绑带、鞍形夹或耐老化的塑

5

DB11/T1008-2024

料夹将电缆固定在管子或方阵支架上。接线完毕后,应盖上接线盒盖板。当有多

个子方阵时,接线可通过分线盒或接线箱集中后输出;

6光伏方阵角度和定位应符合设计要求,方阵方位角和方阵倾角安装误差应

为±3°;

7光伏组件与建筑面层之间应留有安装空间和散热间隙,并不得被施工杂物

等填塞;

8光伏组件上正、负极和各种类型传感器接线应正确,压接应牢固,接线盒

应采取防水措施;

9光伏组件金属部件应进行可靠接地,并应符合现行国家标准《电气装置安

装工程接地装置施工及验收规范》GB50169的规定。

4.2.3建筑光伏构件框架与光伏组件支架及其材料应符合设计要求,钢结构的焊

接应符合现行国家标准《钢结构工程施工质量验收标准》GB50205的规定。

4.2.4根据方阵的数量、安装尺寸和优化设计得出的方阵倾角加工方阵支架和框

架,其尺寸应符合设计要求。

4.2.5光伏组件支架应按设计要求采用从钢筋混凝土基座中伸出的钢制热镀锌等

防腐连接件或不锈钢地脚螺栓等方法固定在基座上,位置

定制服务