T/CAMDI 161-2025 医疗器械灭菌 环氧乙烷灭菌过程 生物指示物放行操作指南
T/CAMDI 161-2025 Sterilization of Medical Devices—Ethylene Oxide Sterilization Process—Operational Guidance on the Release of Biological Indicators
基本信息
发布历史
-
2025年12月
研制信息
- 起草单位:
- 江苏省药品监督管理局审核查验中心、南微医学科技股份有限公司、广州维力医疗器械股份有限公司
- 起草人:
- 余洋、崔佳、闫舒、李宁、徐宏剑、陈云桂、易俊杰
- 出版信息:
- 页数:16页 | 字数:- | 开本: -
内容描述
ICS11.040.01
CCSC30
团体标准
T/CAMDI161—2025
医疗器械灭菌环氧乙烷灭菌过程
生物指示物放行操作指南
SterilizationofMedicalDevices—EthyleneOxideSterilizationProcess—Operational
GuidanceontheReleaseofBiologicalIndicators
2025-12-25发布2025-12-25实施
中国医疗器械行业协会发布
T/CAMDI161—2025
目次
前言.........................................................................................................................................................II
引言.......................................................................................................................................................III
1范围...................................................................................................................................................................1
2规范性引用文件...............................................................................................................................................1
3术语和定义.......................................................................................................................................................1
4生物指示物原理和放行依据...........................................................................................................................1
5生物指示物选择...............................................................................................................................................2
6设备和材料.......................................................................................................................................................2
7灭菌产品及其生产环境...................................................................................................................................2
8灭菌过程及设施安全.......................................................................................................................................3
9灭菌过程相关供应商的管理...........................................................................................................................3
10灭菌过程确认和日常控制.............................................................................................................................3
11生物指示物测试.............................................................................................................................................4
12数据记录.........................................................................................................................................................4
13产品的灭菌放行.............................................................................................................................................5
14变更控制和再鉴定.........................................................................................................................................6
附录A(资料性)灭菌车间安全有效性检查表示例.........................................................................8
附录B(规范性)生物指示物试验方法...........................................................................................10
参考文献.................................................................................................................................................11
I
T/CAMDI161—2025
前言
本文件按照GB/T1.1—2020《标准化工作导则第1部分:标准化文件的结构和起草规则》的规定
起草。
请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。本
文件由中国医疗器械行业协会提出。
本文件由中国医疗器械行业协会医疗器械包装专业委员会归口。
本文件起草单位:江苏省药品监督管理局审核查验中心、南微医学科技股份有限公司、广州维力医疗
器械股份有限公司
本文件主要起草人:余洋、崔佳、闫舒、李宁、徐宏剑、陈云桂、易俊杰本
文件首次发布于2025年12月。
II
T/CAMDI161—2025
引言
环氧乙烷灭菌作为一种成熟高效的灭菌技术,已在医疗健康等领域得到广泛应用。目前,国内对灭菌
后产品的放行主要以产品无菌检查结果为依据。GB18279—2023虽明确了灭菌后产品物理参数及生物指示
物确认的准则,但未规定具体操作规范,致使生物指示物放行环节缺乏统一的操作依据。
生物指示物作为确认灭菌过程有效性的核心工具,其含有的特定微生物数量与抗力特性(D值)是确
认无菌保证水平(SAL)能否稳定达到10⁻⁶的关键因素。本文件围绕生物指示物全生命周期管理与灭菌过
程控制,系统规定了生物指示物选择、设备与材料、灭菌产品及环境控制、灭菌过程及设施安全、供应商
管理、过程确认与日常控制、生物指示物测试、数据记录、灭菌放行、变更控制和再鉴定等全链条技术要
求。
在过程控制环节,重点规范人员资质、仪器验证、过程挑战装置(PCD)设计与摆放、生物指示物
管理、产品微生物状态监控等关键要素,确保灭菌过程在动态生产环境中保持稳定。
在放行准则方面,明确需同时满足两项条件:一是常规过程记录数据(如温度、压力、时间等)符合
灭菌过程规范,二是生物指示物测试结果为无微生物生长;同时,需考虑环氧乙烷(EO)残留量、2-氯
乙醇(ECH)残
定制服务
推荐标准
- DB65/T 4988-2026 干旱区潜在自然植被分布判别规范 2026-07-24
- DB65/T 5020-2026 儿童福利机构 社会工作服务管理规范 2026-07-24
- DB65/T 5022-2026 风力侵蚀监测技术规程 2026-07-24
- DB65/T 5028-2026 特殊儿童个别化教学指南 2026-07-24
- DB65/T 5019-2026 儿童福利机构 儿童出入院服务规范 2026-07-24
- DB65/T 5024-2026 生物土壤结皮调查技术规范 2026-07-24
- DB65/T 5026-2026 残疾儿童家庭康复指导服务指南 2026-07-24
- DB65/T 5021-2026 条堆式翻抛发酵生产有机肥机械化技术规范 2026-07-24
- DB65/T 4987-2026 绿洲水土平衡快速诊断与评估规范 2026-07-24
- DB65/T 5017-2026 儿童福利机构 长期卧床儿童康复服务规范 2026-07-24