DB11/T 1104-2014 地面辐射供暖工程防水施工和验收规程

DB11/T 1104-2014 Ground radiation heating engineering waterproof construction and acceptance regulations

北京市地方标准 简体中文 现行 页数:31页 | 格式:PDF

基本信息

标准号
DB11/T 1104-2014
标准类型
北京市地方标准
标准状态
现行
中国标准分类号(CCS)
国际标准分类号(ICS)
发布日期
2014-06-27
实施日期
2014-10-01
发布单位/组织
北京市质量技术监督局
归口单位
北京市住房和城乡建设委员会
适用范围
-

发布历史

研制信息

起草单位:
起草人:
出版信息:
页数:31页 | 字数:- | 开本: -

内容描述

ICS

备案号

北京市地方标准

DB11

DB11/T1104-2014

地面辐射供暖工程防水施工和验收规程

Specificationofconstructionandacceptancefor

waterproofingoffloorradiantheatingbuilding

2014年—06—25发布2014年—10—01实施

北京市质量技术监督局发布

北京市住房和城乡建设委员会

前言

本规程为推荐性标准。

根据北京市质量技术监督局《关于印发2012年北京市地方标准制修订项目计划的

通知》京质监标〔2012〕136号的要求,由北京市建筑工程物资协会会同北京市建筑材

料质量监督检验站为主编单位,会同有关单位共同编制本规程。编制组广泛听取专家意

见和调查研究,认真总结了近些年来地面辐射供暖防水施工的经验和教训的基础上编制

了本标准。

本标准内容为:

1总则、2基本规定、3材料、4构造、5施工、6质量验收、附录。

本规程由北京市建设工程物资协会、北京市建筑材料质量监督检验站共同提出并编

写。

本规程由北京市住房和城乡建设委员会、北京市质量技术监督局共同负责管理,本

规程由北京市住房和城乡建设委员会归口并负责组织实施,北京市建设工程物资协会负

责解释。

为使规程更好服务于北京市地区地面辐射供暖防水工程,请各单位在执行过程中,

总结经验,并将宝贵意见和建议反馈给北京市建设工程物资协会。

地址:北京市西城区南礼士路头条3号

电话:88070910,传真:68012490

邮箱:jhr88070287@

主编单位:北京市建设工程物资协会

北京市建筑材料质量监督检验站

参加单位:北京世纪洪雨科技有限公司、北京建国伟业防水材料有限公司、北京东

方雨虹防水技术股份有限公司、北京中建友建筑材料有限公司、北京龙阳伟业科技股份

有限公司、北京圣洁防水材料有限公司、北京中联天盛建材有限公司、北京普石防水材

料有限公司、北京金雨伞防水材料科技有限公司、北京金盾建材防水有限公司、北京建

海中建国际防水材料有限公司

标准主要起草人:金惠荣杨永起檀春丽邹仲元李文超杜昕孙哲

熊卫锋吴进明闫志刚陈晓孙双林唐景坤薛邦田

李勇卫向阳孙兢环

标准主要审查人:林寿张思成邓有源王翠芬王军民王卫国贾兰琴

目次

1总则······································································································1

2基本规定·······························································································2

3材料······································································································3

3.1一般规定··························································································3

3.2材料性能··························································································3

4构造······································································································5

4.1一般规定··························································································5

4.2地面辐射供暖工程防水构造··································································6

5施工······································································································8

5.1一般规定··························································································8

5.2施工准备··························································································8

5.3聚合物乳液防水涂料施工·····································································8

5.4聚合物水泥防水涂料、聚合物防水砂浆及浆料施工····································9

5.5单组份聚氨酯(聚脲)防水涂膜施工····················································10

5.6掺防水剂防水砂浆施工······································································10

5.7水泥基渗透结晶型防水材料施工··························································10

5.8喷涂速凝橡胶沥青防水涂料施工···························································11

5.9自粘防水卷材施工要点·······································································11

5.10湿铺防水卷材施工············································································12

5.11聚乙烯丙纶复合防水卷材施工·····························································12

5.12树脂类高分子防水卷材施工································································12

6质量验收·····························································································14

6.1一般规定························································································14

6.2主控项目························································································14

6.3一般项目························································································14

附录A防水层厚度

本规程用词说明·························································································16

引用标准目录····························································································17

条文说明··································································································18

Contents

1Generalprovisions··················································································1

2GeneralRequirements················································································2

3Materials································································································3

3.1GeneralRequirements···········································································3

3.2Materialproperties···············································································3

4Structure·································································································5

4.1GeneralRequirements···········································································5

4.2WaterproofingStructureofFloorHeating····················································6

5Construction···························································································8

5.1GeneralRequirements···········································································8

5.2ConstructionPreparation········································································8

5.3Polymeremulsionwaterproofcoating·························································8

5.4Polymercementwaterproofcoating/mortar/sturty······································9

5.5Onecomponentpolyurethanewaterproofcoating·········································10

5.6Mortarwaterproofagent·······································································10

5.7Cementitiouscapillarycrystallinewaterproofmaterial···································10

5.8WetInstalledwaterproofsheets/waterproofsheetwithself-adheringlayers···········11

5.9Self-adheringwaterproofsheets·······························································11

5.10WetInstalledwaterproofsheets/waterproofsheetwithself-adheringlayers········12

5.11Polyethylenepolypropylenefibercompositewaterproofsheets·······················12

5.12Resinpolymerwaterproofsheets···························································12

6QualityAcceptance··················································································14

6.1GeneralRequirements·········································································14

6.2DominantItem··················································································14

6.3GeneralItem····················································································14

AppendinAwaferpooflayerthickness

ExplanationofWordinginThisSpecification·······················································16

ListofQuotedStandards················································································17

ExplanationofProvision················································································18

1总则

1.0.1为规范地面辐射供暖工程防水的施工和验收,做到技术先进、经济合理、环保安

全、确保防水施工质量,制定本规程。

1.0.2本规程适用于新建扩建和改建的公共与民用建筑的起居室、客厅、办公室和卫生

间、浴室、厨房等采用热水地面辐射的供暖工程防水施工和验收。

1.0.3地面辐射供暖工程防水施工和质量验收除应遵照本规程的规定外,尚应符合现行

国家和北京市有关标准的规定。

1

2基本规定

2.0.1地面辐射热水供暖工程防水施工应遵循因地制宜、安全环保、经济合理的原则,

其设计、施工和验收应符合现行行业标准《住宅室内防水工程技术规程》JGJ298的规定。

2.0.2地面辐射热水供暖工程防水施工应根据建筑设计要求确定,选用符合环保要求的

防水材料和工程做法。

2.0.3在卫生间、浴室、厨房等部位应采用上、下层均设置防水层,验收时应进行蓄水

试验。

2

3材料

3.1一般规定

3.1.1地面辐射供暖工程防水采用的防水材料宜选用防水涂料、聚合物防水砂浆、砂浆

防水剂和防水卷材等,上述材料的规格型号应符合设计要求,材料性能应符合现行国家、

行业和北京市地方标准规定。

3.1.2地面辐射供暖工程选用的防水材料,其有害物质限量应符合现行国家标准和北京

市地方标准的相关规定。各类无机类防水材料的放射性应符合《建筑材料放射性核素限

量》GB6566的规定。

3.2材料性能

3.2.1聚合物乳液防水涂料应符合现行行业标准《聚合物乳液建筑防水涂料》JC/T864

的规定。

3.2.2单组份聚氨酯防水涂料应符合现行国家标准《聚氨酯防水涂料》GB/T19250的规

3.2.3聚合物

定制服务