DB37/T 3460-2018 山东省固定污染源废气 颗粒物中铜的测定 石墨炉原子吸收分光光度法
DB37/T 3460-2018 Determination of Copper in Particulate Matter from Fixed Source Wastes in Shandong Province by Graphite Furnace Atomic Absorption Spectrometry
基本信息
发布历史
-
2018年12月
研制信息
- 起草单位:
- 起草人:
- 出版信息:
- 页数:14页 | 字数:- | 开本: -
内容描述
ICS13.040.01
Z25
DB37
山东省地方标准
DB37/T3460—2018
山东省固定污染源废气颗粒物中铜的测定
石墨炉原子吸收分光光度法
StationarysourceemissionofShandong-Determinationofcopperinambient
particulatematter-Graphiticfurnaceatomicabsorptionspectrophotometricmethod
2018-12-29发布2018-01-29实施
山东省市场监督管理局发布
DB37/T3460—2018
目次
前言...............................................................................III
1范围...............................................................................1
2规范性引用文件.....................................................................1
3方法原理...........................................................................1
4干扰和消除.........................................................................1
5试剂和材料.........................................................................2
6仪器和设备.........................................................................2
6.1石墨炉原子吸收分光光度计.......................................................2
6.2光源...........................................................................2
6.3石墨管.........................................................................2
6.4无组织排放废气采样设备.........................................................2
6.5烟尘采样器.....................................................................3
6.6微波消解仪.....................................................................3
6.7可调温电热板...................................................................3
6.8全自动消解仪...................................................................3
6.9剪刀...........................................................................3
6.10镊子..........................................................................3
6.11其他..........................................................................3
7样品...............................................................................3
7.1样品的采集.....................................................................3
7.2现场空白.......................................................................3
7.3样品的保存.....................................................................3
7.4试样的制备.....................................................................3
7.5实验室样品空白的制备...........................................................5
8分析步骤...........................................................................5
8.1石墨炉原子吸收分光光度计工作条件...............................................5
8.2校准...........................................................................5
8.3测定...........................................................................5
8.4空白试验.......................................................................6
9结果计算与表示.....................................................................6
9.1结果计算.......................................................................6
9.2结果表示.......................................................................6
10精密度和准确度....................................................................6
10.1精密度........................................................................6
I
DB37/T3460—2018
10.2准确度........................................................................6
11质量保证和质量控制................................................................6
11.1仪器..........................................................................6
11.2校准曲线......................................................................7
11.3空白试验......................................................................7
11.4平行样........................................................................7
11.5质控样品分析..................................................................7
12注意事项..........................................................................7
13废弃物的处置......................................................................7
附录A(资料性附录)方法检出限和测定下限........................................8
附录B(资料性附录)方法精密度..................................................9
附录C(资料性附录)方法准确度、加标回收率.....................................10
II
DB37/T3460—2018
前言
本标准按照GB/T1.1—2009给出的规则起草。
本标准由山东省生态环境厅提出并监督实施。
本标准由山东省环保标准化技术委员会归口。
本标准起草单位:山东省环境监测中心站、日照市环境监测站。
本标准主要起草人:金玲仁、丁桂英、岳太星、崔兆杰、赵燕芳、郭莲秀、袁显龙、朱丽、侯晨晓、
翟振国、王梅、谷树茂、刘伟。
III
DB37/T3460—2018
山东省固定污染源废气颗粒物中铜的测定石墨炉原子吸收分光光
度法
警告:实验中使用的硝酸、盐酸、氢氟酸具有挥发性和腐蚀性,操作时应按要求佩戴防护用品,整
个实验过程必须在通风橱中进行操作。
1范围
本标准规定了测定山东省固定污染源无组织排放和有组织排放废气颗粒物中铜的石墨炉原子吸收
分光光度法。
本标准适用于固定污染源无组织排放和有组织排放废气颗粒物中铜的测定。
当无组织排放废气采样量为10m3(标准状态),有组织排放废气采样量为2.0m3(标准状态干烟气)
时,本标准采用不同前处理方法的检出限和测定下限见附录A。
2规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文
件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
GB/T16157固定污染源排气中颗粒物测定与气态污染物采样方法
HJ/T48烟尘采样器技术条件
HJ/T55大气污染物无组织排放监测技术导则
HJ194环境空气质量手工监测技术规范
HJ/T374总悬浮颗粒物采样器技术要求及检测方法
HJ/T397固定源废气监测技术规范
3方法原理
本方法采用石英纤维滤膜采集固定污染源无组织排放废气中的颗粒物,采用石英纤维滤筒采集有组
织排放废气中的颗粒物,样品经预处理得到待测溶液。利用石墨炉原子吸收法测定待测溶液中的浓度,
计算得出样品中铜的含量。
4干扰和消除
用连续光源背景校正法或塞曼偏振光校正法或自吸收法或邻近的非特征吸收线校正法扣除背景。通
过样品稀释降低样品中的基体浓度,或在试样中加入基体改进剂,使其在干燥或灰化阶段与试样发生化
学变化,增加基体的挥发性或改变被测元素的挥发性,以消除干扰。
以氯化钯-硝酸镁溶液作为基体改进剂,10mg/L的钙、镁、锰、钒、钾、钴、铁、钼、锑、铊、铍、
铝、钡无明显共存干扰。
定制服务
推荐标准
- DB33/T 286.3-2000 珠茶 第3部分:栽培管理 2000-10-08
- DB33/T 261.3-1999 笋竹两用毛竹林 第三部分:主要病虫害综合防治 1999-12-01
- DB33/T 279-2000 出口冷冻桔片检验规程 2000-07-07
- DB33/T 280-2000 出口手动液压托盘搬运车检验规程 2000-07-07
- DB33/T 261.5-1999 笋竹两用毛竹林 第五部分:商品竹 1999-12-01
- DB33/T 278-2000 出口藕粉检验规程 2000-07-07
- DB33/T 295.2-2000 江山白羽乌骨鸡 第2部分:雏鸡 2000-11-28
- DB33/T 286.1-2000 珠茶 第1部分:茶树良种繁育 2000-10-08
- DB33/T 282-2000 出口组合电线检验规程 2000-07-07
- DB33/ 295.1-2000 江山白羽乌骨鸡 第1部分:种鸡 2000-11-28