GB/T 36994-2026 风能发电系统 风力发电机组电网适应性测试规程

GB/T 36994-2026 Wind energy generation systems—Test procedure of grid adaptability for wind turbines

国家标准 中文简体 即将实施 页数:36页 | 格式:PDF

基本信息

标准号
GB/T 36994-2026
标准类型
国家标准
标准状态
即将实施
中国标准分类号(CCS)
国际标准分类号(ICS)
发布日期
2026-09-28
实施日期
2027-01-01
发布单位/组织
国家市场监督管理总局、国家标准化管理委员会
归口单位
全国风力发电标准化技术委员会(SAC/TC 50)
适用范围
本文件规定了风力发电机组电网适应性测试的基本要求、技术要求、测试平台、测试设备、测试内容与方法和测试报告内容。
本文件适用于并网型风力发电机组。

发布历史

文前页预览

研制信息

起草单位:
中国电力科学研究院有限公司、金风科技股份有限公司、中国农业机械化科学研究院呼和浩特分院有限公司、上海电气风电集团股份有限公司、国网甘肃省电力公司、国网内蒙古东部电力有限公司、深圳市禾望电气股份有限公司、深圳国金电力新能设计院有限公司、远景能源有限公司、国网吉林省电力有限公司电力科学研究院、国网甘肃省电力公司电力科学研究院、中车山东风电有限公司、运达能源科技集团股份有限公司、国网四川综合能源服务有限公司四川电力工程分公司、国网宁夏电力有限公司电力科学研究院、中车株洲电力机车研究所有限公司风电事业部、阳光电源股份有限公司、国网辽宁省电力有限公司电力科学研究院、国网内蒙古东部电力有限公司电力科学研究院、明阳智慧能源集团股份公司
起草人:
秦世耀、王瑞明、杨志千、陈晨、段月、朱志权、齐琛、徐宏雷、胡浩、代林旺、李东坡、徐婷、房新雨、张宗宝、朱宏毅、赵奉斌、许国东、冯晓伟、苏鹏、邓景云、任勇、陈林、吴玉杨、戈阳阳、王达、郭江涛、刘闯、史俊伟、张旭日、王菡之、付永涛、李钢强、于雪原、余清清、庞家猛
出版信息:
页数:36页 | 字数:58 千字 | 开本: 大16开

内容描述

ICS27.180

CCSF11

中华人民共和国国家标准

GB/T36994—2026

代替GB/T36994—2018

风能发电系统

风力发电机组电网适应性测试规程

Windenergygenerationsystems—Testprocedureofgridadaptabilityforwind

turbines

2026⁃09⁃28发布2027⁃01⁃01实施

国家市场监督管理总局

国家标准化管理委员会发布

GB/T36994—2026

目次

前言··························································································································Ⅲ

1范围·······················································································································1

2规范性引用文件········································································································1

3术语和定义··············································································································1

4基本要求·················································································································2

5技术要求·················································································································2

5.1电压偏差适应性··································································································2

5.2频率扰动适应性··································································································2

5.3三相电压不平衡适应性·························································································2

5.4闪变适应性········································································································2

5.5谐波电压适应性··································································································2

5.6短路比适应性·····································································································3

5.7相角变化适应性··································································································3

5.8惯量响应···········································································································3

5.9一次调频···········································································································3

5.10阻抗特性··········································································································4

6测试平台·················································································································4

6.1现场测试···········································································································4

6.2全尺寸地面试验平台测试······················································································4

7测试设备·················································································································5

7.1电网扰动模拟装置·······························································································5

7.2可调阻抗装置·····································································································6

7.3测量设备及数据··································································································7

8测试内容与方法········································································································7

8.1电压偏差适应性··································································································7

8.2频率扰动适应性··································································································8

8.3三相电压不平衡适应性························································································10

8.4闪变适应性·······································································································10

8.5谐波电压适应性·································································································11

8.6短路比适应性····································································································12

8.7相角变化适应性·································································································13

8.8惯量响应··········································································································14

8.9一次调频··········································································································15

Ⅰ

GB/T36994—2026

8.10阻抗特性········································································································16

9测试报告内容·········································································································17

9.1测试报告··········································································································17

9.2不确定度··········································································································17

附录A(资料性)风力发电机组升压变压器高压侧短路比计算方法········································18

附录B(资料性)控制系统响应性能指标说明··································································19

附录C(资料性)报告格式样本·····················································································20

C.1测试项目基本信息·····························································································20

C.2风力发电机组基本信息·······················································································20

C.3风力发电机组主要零部件信息··············································································21

C.4风力发电机组升压变压器信息··············································································21

C.5项目其他信息···································································································21

C.6测试结果·········································································································22

附录D(资料性)风力发电机组阻抗计算方法···································································28

D.1正序阻抗·········································································································28

D.2负序阻抗·········································································································28

参考文献····················································································································29

Ⅱ

GB/T36994—2026

前言

本文件按照GB/T1.1—2020《标准化工作导则第1部分:标准化文件的结构和起草规则》的规定

起草。

本文件代替GB/T36994—2018《风力发电机组电网适应性测试规程》,与GB/T36994—2018

相比,除结构调整和编辑性改动外,主要技术变化如下:

——更改了范围(见第1章,2018年版的第1章);

——删除了术语“风力发电机组电网适应性”“空载测试”“负载测试”和“有功调频系数”(见2018年

版的第3章);

——更改了术语“测试点”“风力发电机组惯量响应”的定义(见3.1、3.2,2018年版的3.2、3.5);

——增加了术语“风力发电机组一次调频”“风力发电机组升压变压器高压侧短路比”和“风力发电

机组阻抗特性”(见第3章);

——删除了符号(见2018年版的第4章);

——更改了基本要求(见第4章,2018年版的第5章);

——增加了技术要求,区分技术要求与测试内容(见第5章);

——更改了“频率扰动适应性”技术要求及其测试方法(见5.2、8.2,2018年版的第6章、第8章);

——增加了对频率变化率适应性技术要求及其测试方法(见5.2、8.2,2018年版的第6章、第8章);

——更改了“惯量响应”技术要求及其测试方法(见5.8、8.8,2018年版的第6章、第8章);

——更改了“一次调频”技术要求及其测试方法(见5.9、8.9,2018年版的第6章、第8章);

——增加了“短路比适应性”“相角变化适应性”“阻抗特性”技术要求及其测试方法(见5.6、5.7、

5.10、8.6、8.7、8.10);

——增加了测试平台,增加了“全尺寸地面试验平台测试”环境(见第6章);

——更改了“电网扰动模拟装置”的运行条件和主要技术指标(见7.1,2018年版的7.1);

——增加了测试设备“可调阻抗装置”(见7.2);

——更改了测量设备中对通道采样率的要求(见7.3,2018年版的7.2);

——更改了“电压偏差适应性”“频率扰动适应性”“谐波电压适应性”测试内容与方法(见8.1、

8.2.1、8.5,2018年版的第6章、第8章);

——更改了“测试报告内容”(见第9章,2018年版的第9章);

请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。

本文件由中国机械工业联合会提出。

本文件由全国风力发电标准化技术委员会(SAC/TC50)归口。

本文件起草单位:中国电力科学研究院有限公司、金风科技股份有限公司、中国农业机械化科学研

究院呼和浩特分院有限公司、上海电气风电集团股份有限公司、国网甘肃省电力公司、国网内蒙古东部

电力有限公司、深圳市禾望电气股份有限公司、深圳国金电力新能设计院有限公司、远景能源有限公

司、国网吉林省电力有限公司电力科学研究院、国网甘肃省电力公司电力科学研究院、中车山东风电有

限公司、运达能源科技集团股份有限公司、国网四川综合能源服务有限公司四川电力工程分公司、国网

宁夏电力有限公司电力科学研究院、中车株洲电力机车研究所有限公司风电事业部、阳光电源股份有

限公司、国网辽宁省电力有限公司电力科学研究院、国网内蒙古东部电力有限公司电力科学研究院、

明阳智慧能源集团股份公司。

Ⅲ

GB/T36994—2026

本文件主要起草人:秦世耀、王瑞明、杨志千、陈晨、段月、朱志权、齐琛、徐宏雷、胡浩、代林旺、李东坡、

徐婷、房新雨、张宗宝、朱宏毅、赵奉斌、许国东、冯晓伟、苏鹏、邓景云、任勇、陈林、吴玉杨、戈阳阳、

王达、郭江涛、刘闯、史俊伟、张旭日、王菡之、付永涛、李钢强、于雪原、余清清、庞家猛。

本文件于2018年首次发布,本次为第一次修订。

Ⅳ

GB/T36994—2026

风能发电系统

风力发电机组电网适应性测试规程

1范围

本文件规定了风力发电机组电网适应性测试的基本要求、技术要求、测试平台、测试设备、测试内

容与方法和测试报告内容。

本文件适用于并网型风力发电机组。

2规范性引用文件

下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。其中,注日期的引用文

件,仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于

本文件。

GB/T12325电能质量供电电压偏差

GB/T12326电能质量电压波动和闪变

GB/T14549电能质量公用电网谐波

GB/T15543电能质量三相电压不平衡

GB/T19963.1风电场接入电力系统技术规定第1部分:陆上风电

GB/T19963.2风电场接入电力系统技术规定第2部分:海上风电

GB/T24337电能质量公用电网间谐波

GB/T40082风力发电机组传动链地面测试技术规范

GB/T40594电力系统网源协调技术导则

JJF1059.1测量不确定度评定与表示

3术语和定义

下列术语和定义适用于本文件。

3.1

测试点pointoftestofwindturbine

为测试装置与风力发电机组升压变压器高压侧的连接点。

注:测试点是电压或频率变化的产生点。

3.2

风力发电机组惯量响应inertiaresponseofwindturbine

当电力系统频率快速变化时,风力发电机组响应于系统频率变化率快速调整自身有功功率的能力。

[来源:GB/T19963.1—2021,3.11,有修改]

3.3

风力发电机组一次调频primaryfrequencyregulationofwindturbine

当电力系统频率偏离死区时,风力发电机组响应于系统频率偏差快速调整自身有功功率的能力。

[来源:GB/T19963.1—2021,3.12,有修改]

1

定制服务

    推荐标准